Problem 01
Drum Turns But Stays Cold
The drum spins on schedule and everything inside stays cool and damp. Electric models usually point to an open heating coil or a blown safety fuse, while gas models tend to have an igniter too weak to trigger the valve. We measure each piece, so only the failed one goes on the invoice.
While You Wait
At the electrical panel, check whether one side of the two-pole dryer breaker has dropped; a dryer can tumble on one leg without ever heating. Gas owners should confirm the yellow-handled valve is in line with the pipe.
Usual Suspects